Pin 1 - White with orange stripePin 2 - Solid orangePin 3 - White with green stripePin 4 - Solid bluePin 5 - White with blue stripePin 6 - Solid greenPin 7 - White with brown stripePin 8 - Solid Brown
  • You want to use the T568B standard for adding connectors to your Cat5 cable. Starting with pin 1, which order should you use for the wires within the connector?
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards.term-6Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards.Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
  • You are working with 25 pair wires and 66 blocks. You have pushed the wires onto the 66 block, but now you need to cut off the excess end of each wire.Which tool should you use?
DemarcWhen you contract with a local exchange carrier (LEC) for data or telephone services, they install a physical cable and a termination jack onto your premises. The demarcation point (demarc) is the line that marks the boundary between the telco equipment and the private network or telephone system. Typically, the LEC is responsible for all equipment on one side of the demarc, and the customer is responsible for all equipment on the other side of the demarc.A punch down block is a block used to connect individual copper wires together. While the demarc might terminate in a punch down block, punch down blocks are used within other locations at the customer site.An intermediate distribution frame (IDF) is a smaller wiring distribution point within a building. IDFs are typically located on each floor directly above the main distribution frame (MDF), although additional IDFs can be added on each floor as necessary. A vertical cross connect connects the IDF to the MDF on a different floor.
  • Which of the following terms identifies the wiring closet in the basement or a ground floor that typically includes the demarcation point?
  • Which of the following describes the point where the service provider's responsibility to install and maintain wiring and equipment ends, and the customer's responsibility begins?
  • Which of the following methods would you use to create a crossover cable?
  • Which of the following is used to terminate individual wires from a 25 pair or 100 pair cable using female RJ45 ports?
Vertical cross connectA vertical cross connect joins the main distribution frame (MDF) on the main floor to intermediate distribution frames (IDFs) on upper floors. Cabling runs vertically (up and down) between the MDF and the IDFs.A horizontal cross connect joins IDFs on the same floor. Cabling runs horizontally (sideways) between the IDFs. A smart jack is a special loopback plug installed at the demarcation point for a WAN service. Technicians at the central office can send diagnostic commands to the smart plug to test connectivity between the central office and the demarc.A demarc extension extends the demarcation point from its original location to another location within the building. The demarc extension typically consists of a single wire bundle that attaches to the existing demarc and supplies a termination point to a different location. You might need a demarc extension if your network occupies an upper floor of a building. The LEC will typically install the demarc into the MDF on the bottom floor, and you will need to install an extension to place the demarc into the IDF on your floor.
  • You have a network that occupies all three floors of a building. The WAN service provider has installed the line for the WAN service into the building in a wiring closet on the main floor. You have a wiring closet on the two remaining floors directly above the wiring closet on the main floor.What would you use to connect the wiring closets together?
  • You have a network that occupies both floors of a building. The WAN service provider has installed the line for the WAN service in a wiring closet on the main floor.You have a second wiring closet on the second floor directly above the wiring closet that holds the demarc. Which of the following terms describes the closet on the second floor?
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards.term-6Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards.Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
Crimping toolYou should use a crimping tool designed for RJ45 connectors to attach connectors to UTP cable.
  • Which pins in an RJ45 connector are used to transmit data when used on a 100BaseT Ethernet network? (Select two.)
  • You want to use the T568B standard for adding connectors to your Cat5 cable. Starting with pin 1, which order should you use for the wires within the connector?
  • You are building network cables and attaching RJ45 connectors to each end. Which tool do you need for this task?
  • You are working with 25 pair wires and 66 blocks. You have pushed the wires onto the 66 block, but now you need to cut off the excess end of each wire.Which tool should you use?
Patch panelA patch panel is a device that typically connects individual stranded wires into female RJ45 connectors. For example, you might connect 4 pairs of wires from a punch down block to a port on the patch panel. On the patch panel, you then connect drop cables (cables with RJ45 connectors) to the patch panel on one end and a computer on the other end.Use 66 and 110 blocks to connect individual wires within a wiring closet. These punch down blocks connect the individual wires together, but do not terminate in RJ45 connectors.A horizontal cross connect connects IDFs on the same floor.
  • Which of the following methods would you use to create a crossover cable?
  • Which of the following describes the point where the service provider's responsibility to install and maintain wiring and equipment ends, and the customer's responsibility begins?
  • Which of the following is used to terminate individual wires from a 25 pair or 100 pair cable using female RJ45 ports?
  • Which of the following terms identifies the wiring closet in the basement or a ground floor that typically includes the demarcation point?
Pin 1Pin 2On a 100BaseT network cable, the RJ45 pin-outs are as follows:Pin 1: Tx+Pin 2: Tx-Pin 3: Rx+Pin 4: UnusedPin 5: UnusedPin 6: Rx-Pin 7: UnusedPin 8: UnusedFor a 100BaseT cable, Pins 1 and 2 are used to transmit data; pins 3 and 6 are used to receive data.
  • Which recommendation should you follow while using 110 blocks for connecting Cat 5 and higher data cables?
  • Which pins in an RJ45 connector are used to transmit data when used on a 100BaseT Ethernet network? (Select two.)
  • Which of the following is used to terminate individual wires from a 25 pair or 100 pair cable using female RJ45 ports?
  • Which of the following methods would you use to create a crossover cable?
Use the T568A standard on one connector and the T568B standard on the other connector.The easiest way to create a crossover cable is to arrange the wires in the first connector using the T568A standard and arrange the wires in the second connector using the T568B standard. A crossover cable connects the transmit pins on one connector to the receive pins on the other connector (pin 1 to pin 3 and pin 2 to pin 6).
  • Which of the following terms identifies the wiring closet in the basement or a ground floor that typically includes the demarcation point?
  • Which of the following is used to terminate individual wires from a 25 pair or 100 pair cable using female RJ45 ports?
  • Which of the following describes the point where the service provider's responsibility to install and maintain wiring and equipment ends, and the customer's responsibility begins?
  • Which of the following methods would you use to create a crossover cable?
IDFAn intermediate distribution frame (IDF) is a wiring distribution point within a building that is smaller than the MDF. IDFs are typically located on each floor directly above the MDF, but you can place additional IDFs on each floor as necessary.The main distribution frame (MDF) is the main wiring point for a building. The MDF is typically located on the bottom floor or basement. The LEC typically installs the demarc to the MDF. A vertical cross connect connects the MDF on the main floor to IDFs on upper floors. Cabling runs vertically (up and down) between the MDF and the IDFs. A horizontal cross connect connects IDFs on the same floor. Cabling runs horizontally (sideways) between the IDFs.A demarc extension extends the demarcation point from its original location to another location within the building.
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards.Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
  • You have a network that occupies both floors of a building. The WAN service provider has installed the line for the WAN service in a wiring closet on the main floor.You have a second wiring closet on the second floor directly above the wiring closet that holds the demarc. Which of the following terms describes the closet on the second floor?
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards.term-6Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
  • You have a network that occupies all three floors of a building. The WAN service provider has installed the line for the WAN service into the building in a wiring closet on the main floor. You have a wiring closet on the two remaining floors directly above the wiring closet on the main floor.What would you use to connect the wiring closets together?
Pin 1 - White with green stripePin 2 - Solid greenPin 3 - White with orange stripePin 4 - Solid bluePin 5 - White with blue stripePin 6 - Solid orangePin 7 - White with brown stripePin 8 - Solid brown
  • You are working with 25 pair wires and 66 blocks. You have pushed the wires onto the 66 block, but now you need to cut off the excess end of each wire.Which tool should you use?
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards.Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
  • You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards.term-6Drag the UTP wire on the left to the correct pin in the RJ45 connector on the right.
  • You want to use the T568B standard for adding connectors to your Cat5 cable. Starting with pin 1, which order should you use for the wires within the connector?